Review



airyscan joint deconvolution processing module  (Carl Zeiss)


Bioz Verified Symbol Carl Zeiss is a verified supplier
Bioz Manufacturer Symbol Carl Zeiss manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    Carl Zeiss airyscan joint deconvolution processing module
    ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an <t>Airyscan</t> detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.
    Airyscan Joint Deconvolution Processing Module, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 94/100, based on 31 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/airyscan joint deconvolution processing module/product/Carl Zeiss
    Average 94 stars, based on 31 article reviews
    airyscan joint deconvolution processing module - by Bioz Stars, 2026-04
    94/100 stars

    Images

    1) Product Images from "Plakoglobin transmits tension across VE-cadherin for vascular leak formation and leukocyte diapedesis"

    Article Title: Plakoglobin transmits tension across VE-cadherin for vascular leak formation and leukocyte diapedesis

    Journal: The EMBO Journal

    doi: 10.1038/s44318-026-00732-0

    ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an Airyscan detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.
    Figure Legend Snippet: ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an Airyscan detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.

    Techniques Used: Staining, Microscopy



    Similar Products

    99
    Oxford Instruments imaris image processing module
    Imaris Image Processing Module, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/imaris image processing module/product/Oxford Instruments
    Average 99 stars, based on 1 article reviews
    imaris image processing module - by Bioz Stars, 2026-04
    99/100 stars
      Buy from Supplier

    93
    Genovis Inc processing module b 150 b
    Processing Module B 150 B, supplied by Genovis Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/processing module b 150 b/product/Genovis Inc
    Average 93 stars, based on 1 article reviews
    processing module b 150 b - by Bioz Stars, 2026-04
    93/100 stars
      Buy from Supplier

    94
    Carl Zeiss airyscan joint deconvolution processing module
    ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an <t>Airyscan</t> detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.
    Airyscan Joint Deconvolution Processing Module, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/airyscan joint deconvolution processing module/product/Carl Zeiss
    Average 94 stars, based on 1 article reviews
    airyscan joint deconvolution processing module - by Bioz Stars, 2026-04
    94/100 stars
      Buy from Supplier

    90
    MathWorks Inc data collection and raw data processing modules
    ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an <t>Airyscan</t> detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.
    Data Collection And Raw Data Processing Modules, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/data collection and raw data processing modules/product/MathWorks Inc
    Average 90 stars, based on 1 article reviews
    data collection and raw data processing modules - by Bioz Stars, 2026-04
    90/100 stars
      Buy from Supplier

    93
    Genovis Inc operator processing modules 2435
    ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an <t>Airyscan</t> detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.
    Operator Processing Modules 2435, supplied by Genovis Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/operator processing modules 2435/product/Genovis Inc
    Average 93 stars, based on 1 article reviews
    operator processing modules 2435 - by Bioz Stars, 2026-04
    93/100 stars
      Buy from Supplier

    99
    Sartorius AG incucyte zoom phase only processing module
    ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an <t>Airyscan</t> detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.
    Incucyte Zoom Phase Only Processing Module, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/incucyte zoom phase only processing module/product/Sartorius AG
    Average 99 stars, based on 1 article reviews
    incucyte zoom phase only processing module - by Bioz Stars, 2026-04
    99/100 stars
      Buy from Supplier

    Image Search Results


    ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an Airyscan detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.

    Journal: The EMBO Journal

    Article Title: Plakoglobin transmits tension across VE-cadherin for vascular leak formation and leukocyte diapedesis

    doi: 10.1038/s44318-026-00732-0

    Figure Lengend Snippet: ( A , B ) HUVEC were treated with histamine (100 µM, Sigma-Aldrich) or thrombin (1 U/ml, CalBiochem) for 10 min, or left untreated with equivalent volumes of vehicle (media) as controls. Cells were subsequently fixed, permeabilized and stained for plakoglobin, β-catenin, and VE-cadherin, all visualized in grayscale to ensure unbiased comparative analysis. Higher magnification images (63X) were acquired using a Zeiss LSM 980 confocal microscope equipped with an Airyscan detector ( A ), while lower magnification images (40X) were captured on a Zeiss LSM 880 confocal microscope ( B ). Scale bars, 25 µm.

    Article Snippet: Zeiss LSM 980 Airyscan acquisitions were processed with Airyscan Joint Deconvolution processing module in ZEN blue software (Zeiss) to improve signal-to-noise and spatial resolution; LSM 880 images were used without further deconvolution.

    Techniques: Staining, Microscopy